Fire-door inspections and surveys

Fire door inspections and condition surveys with asset-level evidence.

Commission routine fire-door check programmes or detailed condition surveys under clearly separated scopes, with each door referenced to its location and findings recorded without assuming that every observed issue requires wholesale replacement.

  • Asset-referenced fire-door condition surveys
  • Flat entrance, communal and non-domestic fire-door inspections
  • Routine visual-check programme design and reporting
  • Self-closing devices, ironmongery, glazing, seals and gaps

Request a scoped quotation

What should we quote for fire-door inspections and condition surveys?

Share the premises type, location and number of sites. We’ll confirm the appropriate scope and prepare a no-obligation quotation.

Step 1 of 2

We’ll only use your details to respond to this request. Privacy notice

Scope confirmed firstPremises, systems and required output agreed before instruction.

Appropriate competenceThe delivery route is matched to the agreed specialist scope.

Usable written evidenceReports and findings are returned against the correct site.

Discipline-specific methodThe approach and evidence are matched to fire-door inspections and condition surveys.

Service overview

What should a fire-door inspection establish?

The agreed inspection should identify each door in scope, record the door leaf, frame, gaps, seals, glazing, ironmongery, self-closing action, surrounding construction and visible alterations relevant to performance, and explain any evidence or access limitations. A routine visual check and a detailed specialist condition survey are different instructions and should not be presented as interchangeable.

Get the right scope for my site

Scope of service

A defined instruction, matched to the premises and duty.

Before appointment, we confirm the required output, available evidence, access limitations and the areas, systems or assets included in the instruction.

01

Asset-referenced fire-door condition surveys

02

Flat entrance, communal and non-domestic fire-door inspections

03

Routine visual-check programme design and reporting

04

Self-closing devices, ironmongery, glazing, seals and gaps

05

Available product, installation and maintenance evidence review

06

Prioritised findings and separately scoped remedial recommendations

Reporting output

A clear technical record for the dutyholder.

  • A door schedule tied to the agreed building, floor and location references
  • Recorded observations, photographs and access or evidence limitations
  • Prioritised findings distinguishing maintenance, further review and replacement considerations
  • A clear statement of the inspection depth and matters outside the agreed scope

How it works

From defined instruction to issued report.

  1. 01
    Define the inspection level

    Confirm the building, legal context, door population, records and required inspection depth.

  2. 02
    Set the asset references

    Agree door identifiers, access arrangements, sampling and the evidence to be reviewed.

  3. 03
    Inspect the doors

    Record the visible condition and operation of each accessible door within the agreed scope.

  4. 04
    Issue the findings

    Return the asset schedule, evidence, limitations, priorities and any separately scoped next steps.

Built for the people managing the risk

Support shaped around the duty, premises and decision.

Choose the route closest to your role and property type. The technical scope stays specific to this service while access, communication and reporting reflect the operating environment.

Technical and procurement questions

Scope, duties and deliverables—set out clearly.

The correct service depends on the premises, systems, equipment, use and dutyholder position. These points are confirmed before appointment.

Request a scoped quotation
Are routine fire-door checks the same as a detailed inspection?

No. Routine checks are simple visual and operational checks intended to identify obvious defects. A detailed condition survey is a separately defined specialist inspection of the door assembly, installation condition and available evidence.

Which residential fire doors need quarterly or annual checks?

In England, regulation 10 applies the routine-check duty to blocks containing common parts where the top storey is more than 11 metres above ground. Communal fire doors require checks at least every three months, while best endeavours must be used to check flat entrance doors at least every 12 months. Other maintenance duties can still apply outside that specific regime.

Does missing certification mean a door automatically fails?

No. For an existing flat entrance door, absence of current certification—or absence of intumescent strips and smoke seals—does not on its own mean the door is unfit. Adequacy must be considered through the fire risk assessment, door condition, available evidence and intended performance.

Are repairs included with the survey?

No, unless the written scope expressly includes a separately controlled repair instruction. Survey findings should first identify the door, defect, evidence and priority so an appropriate competent repair or replacement route can be agreed.

Can resident access attempts be recorded?

Yes. The survey or routine-check programme can record appointments, completed checks and inaccessible doors, provided the client agrees the access and communication process in advance.

Request a quotation

Define the premises, required output and timescale.

Tell us about the property, system or equipment involved and what has prompted the instruction. We will confirm the information required before issuing a proposal.

Request a scoped quotation020 8050 4416