Emergency-lighting systems

Emergency-lighting testing with traceable results and limitations.

Scope functional checks, full-duration testing, condition review and planned maintenance around the installed system, escape routes and occupied-building constraints, while keeping system testing separate from any design or coverage appraisal.

  • Routine emergency-lighting functional tests
  • Full-duration discharge testing
  • Self-contained luminaires and central-battery systems
  • Exit-sign and escape-route lighting condition checks

Request a scoped quotation

What should we quote for emergency-lighting testing and maintenance?

Share the premises type, location and number of sites. We’ll confirm the appropriate scope and prepare a no-obligation quotation.

Step 1 of 2

We’ll only use your details to respond to this request. Privacy notice

Scope confirmed firstPremises, systems and required output agreed before instruction.

Appropriate competenceThe delivery route is matched to the agreed specialist scope.

Usable written evidenceReports and findings are returned against the correct site.

Discipline-specific methodThe approach and evidence are matched to emergency-lighting testing and maintenance.

Service overview

What should an emergency-lighting test establish?

The test should identify the premises and luminaires or system in scope, confirm the test method and duration, record operation during loss of the normal supply, identify failures or limitations, and state the next action. Routine functional testing, full-duration discharge testing, maintenance and design verification are different activities.

Get the right scope for my site

Scope of service

A defined instruction, matched to the premises and duty.

Before appointment, we confirm the required output, available evidence, access limitations and the areas, systems or assets included in the instruction.

01

Routine emergency-lighting functional tests

02

Full-duration discharge testing

03

Self-contained luminaires and central-battery systems

04

Exit-sign and escape-route lighting condition checks

05

Logbook, asset schedule and previous-defect review

06

Multi-site testing programmes and evidence control

Reporting output

A clear technical record for the dutyholder.

  • A test record identifying the premises, system, test type and date
  • Luminaire or circuit results at the level included in the agreed scope
  • Recorded failures, battery or lamp observations, access limits and further-investigation needs
  • A clear next testing point and separately identified repair or design-review recommendations

How it works

From defined instruction to issued report.

  1. 01
    Confirm the system

    Review premises use, escape routes, asset information, logbooks and known defects.

  2. 02
    Plan the test

    Agree functional or duration testing, safe timing, access, system recovery and occupied-area controls.

  3. 03
    Test and inspect

    Complete the agreed operation, duration and visible-condition checks and record limitations.

  4. 04
    Issue the results

    Return the test evidence and keep failed items, repairs and design questions as clearly separated next actions.

Built for the people managing the risk

Support shaped around the duty, premises and decision.

Choose the route closest to your role and property type. The technical scope stays specific to this service while access, communication and reporting reflect the operating environment.

Technical and procurement questions

Scope, duties and deliverables—set out clearly.

The correct service depends on the premises, systems, equipment, use and dutyholder position. These points are confirmed before appointment.

Request a scoped quotation
What is the difference between a functional test and a full-duration test?

A functional test checks that the emergency lighting operates when the normal supply is interrupted. A full-duration test runs the system for its rated emergency period and records whether the required operation is sustained. The safe timing and recovery arrangements should be agreed before testing.

How often should emergency lighting be tested?

A typical premises programme includes a monthly functional test and an annual competent full-duration test, alongside routine visual checks. The final regime should reflect the applicable standard, premises fire-safety arrangements, system design and manufacturer information.

Does passing a duration test prove the building has enough emergency lights?

No. A duration test shows how the tested system operated; it does not confirm that the original design, coverage or siting remains adequate after layout or use changes. That may require a separate design review or survey.

Are failed batteries or luminaires replaced automatically?

Only where replacement authority, compatible parts and the necessary competence are included in the instruction. Otherwise failures are recorded and quoted as a separate repair scope.

Can tests be planned outside normal hours?

Yes, where required and agreed. The quotation should account for access, building occupation, alarm or control interfaces, safe escape provision during the test and the recharge or recovery period afterward.

Request a quotation

Define the premises, required output and timescale.

Tell us about the property, system or equipment involved and what has prompted the instruction. We will confirm the information required before issuing a proposal.